Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting64.0 - 160A
Number of poles4
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated voltage220 - 690V
Rated permanent current Iu160A
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Type of control elementToggle
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release160 - 1600A
Adjustment range undelayed short-circuit release160 - 1600A
With switched-off indicatorNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067850R1 | XT2S 160 Ekip LSI In=160A 4p F F In=100%

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

64.0 .. 160A

Number of poles

4

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated voltage

220 .. 690V

Rated permanent current Iu

160A

With under voltage release

Device construction

Built-in device fixed built-in technique

Motor drive optional

Type of control element

Toggle

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Motor drive integrated

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Adjustment range undelayed short-circuit release

160 .. 1600A

With switched-off indicator

Position of connection for main current circuit

Front side

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.