Aleta.hr
Main Product Image

1SDA067895R1 | XT2H 160 Ekip LS/I In=160A 4pFF InN=100%

Code: 1613680

ManufacturerABB
Catalog number1SDA067895R1
EAN code8015644017910

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Integrated earth fault protectionNo
Rated permanent current Iu160A
Adjustment range short-term delayed short-circuit release160 - 1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Number of poles4
Adjustment range undelayed short-circuit release160 - 1600A
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Overload release current setting64.0 - 160A
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
With switched-off indicatorNo
Motor drive optionalYes
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementToggle
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067895R1 | XT2H 160 Ekip LS/I In=160A 4pFF InN=100%

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Integrated earth fault protection

Rated permanent current Iu

160A

Adjustment range short-term delayed short-circuit release

160 .. 1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Number of poles

4

Adjustment range undelayed short-circuit release

160 .. 1600A

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Overload release current setting

64.0 .. 160A

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

With switched-off indicator

Motor drive optional

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Toggle

With under voltage release

Suitable for DIN rail (top hat rail) mounting

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.