Aleta.hr
Main Product Image

1SDA070727R1 | E1.2N 630 EKIP G TOUCH LSIG 3P F F

Code: 1613803

ManufacturerABB
Catalog number1SDA070727R1
EAN code8015644745776

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Overload release current setting252.0 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release945.0 - 9450A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionYes
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Number of auxiliary contacts as change-over contact4
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitBolt connection
With switched-off indicatorYes
Rated permanent current Iu630A
Number of poles3
Complete device with protection unitYes
Position of connection for main current circuitBack side
Type of control elementPush button
Motor drive integratedNo
Degree of protection (IP)IP30
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070727R1 | E1.2N 630 EKIP G TOUCH LSIG 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Overload release current setting

252.0 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

945.0 .. 9450A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Number of auxiliary contacts as change-over contact

4

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Rated permanent current Iu

630A

Number of poles

3

Complete device with protection unit

Position of connection for main current circuit

Back side

Type of control element

Push button

Motor drive integrated

Degree of protection (IP)

IP30

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.