Aleta.hr
Main Product Image

1SDA070745R1 | E1.2B 800 EKIP TOUCH LSI 3P F F

Code: 1613811

ManufacturerABB
Catalog number1SDA070745R1
EAN code8015644745950

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Rated permanent current Iu800A
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1200.0 - 12000A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as change-over contact4
With switched-off indicatorYes
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitBack side
Device constructionBuilt-in device fixed built-in technique
Degree of protection (IP)IP30
Type of control elementPush button
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Overload release current setting320.0 - 800A
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070745R1 | E1.2B 800 EKIP TOUCH LSI 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as change-over contact

4

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Back side

Device construction

Built-in device fixed built-in technique

Degree of protection (IP)

IP30

Type of control element

Push button

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Overload release current setting

320.0 .. 800A

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.