Aleta.hr
Main Product Image

1SDA070784R1 | E1.2B 1000 EKIP TOUCH LI 3P F F

Code: 1613840

ManufacturerABB
Catalog number1SDA070784R1
EAN code8015644746346

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting400.0 - 1000A
Rated permanent current Iu1000A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1500.0 - 15000A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Integrated earth fault protectionNo
With under voltage releaseNo
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Motor drive integratedNo
With switched-off indicatorYes
Motor drive optionalYes
Type of control elementPush button
Degree of protection (IP)IP30
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070784R1 | E1.2B 1000 EKIP TOUCH LI 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

400.0 .. 1000A

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Integrated earth fault protection

With under voltage release

Complete device with protection unit

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Motor drive integrated

With switched-off indicator

Motor drive optional

Type of control element

Push button

Degree of protection (IP)

IP30

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.