1SDA070805R1 | E1.2N 1000 EKIP TOUCH LSI 3P F F

Code: 1613861

ManufacturerABB
Catalog number1SDA070805R1
EAN code8015644746551

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Adjustment range undelayed short-circuit release1500.0 - 15000A
Rated permanent current Iu1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Integrated earth fault protectionNo
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting400.0 - 1000A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Complete device with protection unitYes
Type of control elementPush button
Motor drive optionalYes
Number of poles3
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070805R1 | E1.2N 1000 EKIP TOUCH LSI 3P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Rated permanent current Iu

1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

400.0 .. 1000A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Complete device with protection unit

Type of control element

Push button

Motor drive optional

Number of poles

3

DIN rail (top hat rail) mounting optional

Motor drive integrated

With switched-off indicator