Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Number of poles3
Number of auxiliary contacts as normally closed contact0
Overload release current setting320.0 - 800A
Rated voltage690 - 690V
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Number of auxiliary contacts as change-over contact4
Adjustment range undelayed short-circuit release1200.0 - 12000A
Type of control elementPush button
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
With under voltage releaseNo
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070898R1 | E2.2N 800 EKIP HI-TOUCH LSI 3P FHR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

320.0 .. 800A

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Number of auxiliary contacts as change-over contact

4

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Type of control element

Push button

With switched-off indicator

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

With under voltage release

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Motor drive optional

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.