Aleta.hr
Main Product Image

1SDA070970R1 | E2.2S 1250 EKIP G HI-TOUCH LSIG 3P FHR

Code: 1614006

ManufacturerABB
Catalog number1SDA070970R1
EAN code8015644748203

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu1250A
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release750.0 - 12500A
Adjustment range undelayed short-circuit release1875.0 - 18750A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Overload release current setting500.0 - 1250A
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
With under voltage releaseNo
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementPush button
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA070970R1 | E2.2S 1250 EKIP G HI-TOUCH LSIG 3P FHR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

1250A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

750.0 .. 12500A

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Overload release current setting

500.0 .. 1250A

DIN rail (top hat rail) mounting optional

With switched-off indicator

With under voltage release

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP30

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.