Aleta.hr
Main Product Image

1SDA071013R1 | E2.2H 1600 EKIP DIP LSIG 3P FHR

Code: 1614049

ManufacturerABB
Catalog number1SDA071013R1
EAN code8015644748630

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu1600A
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalNo
Overload release current setting640.0 - 1600A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Number of auxiliary contacts as normally open contact0
Number of poles3
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Complete device with protection unitYes
Motor drive integratedNo
Type of control elementPush button
Degree of protection (IP)IP30
Position of connection for main current circuitBack side
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071013R1 | E2.2H 1600 EKIP DIP LSIG 3P FHR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

1600A

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Overload release current setting

640.0 .. 1600A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Number of poles

3

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Complete device with protection unit

Motor drive integrated

Type of control element

Push button

Degree of protection (IP)

IP30

Position of connection for main current circuit

Back side

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.