Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release2400.0 - 40000A
Rated permanent current Iu4000A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Overload release current setting1600.0 - 4000A
Type of electrical connection of main circuitBolt connection
Type of control elementPush button
Number of poles3
Motor drive integratedNo
Adjustment range undelayed short-circuit release6000.0 - 60000A
Motor drive optionalYes
Complete device with protection unitYes
With switched-off indicatorYes
DIN rail (top hat rail) mounting optionalNo
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact4
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitBack side
Integrated earth fault protectionYes
Degree of protection (IP)IP30
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071226R1 | E4.2V 4000 EKIP TOUCH LSIG 3P FHR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

2400.0 .. 40000A

Rated permanent current Iu

4000A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Overload release current setting

1600.0 .. 4000A

Type of electrical connection of main circuit

Bolt connection

Type of control element

Push button

Number of poles

3

Motor drive integrated

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Motor drive optional

Complete device with protection unit

With switched-off indicator

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Back side

Integrated earth fault protection

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.