Technical specifications

Rated permanent current Iu250A
Number of poles4
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Overload release current setting100.0 - 250A
Degree of protection (IP)IP30
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitBack side
Motor drive integratedNo
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release150.0 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Adjustment range undelayed short-circuit release375.0 - 3750A
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementPush button
With switched-off indicatorYes
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071330R1 | E1.2N 250 EKIP G HI-TOUCH LSIG 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

250A

Number of poles

4

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

100.0 .. 250A

Degree of protection (IP)

IP30

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Back side

Motor drive integrated

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

150.0 .. 2500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Adjustment range undelayed short-circuit release

375.0 .. 3750A

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

With switched-off indicator

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With under voltage release

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection