Aleta.hr
Main Product Image

1SDA071350R1 | E1.2C 630 EKIP G HI-TOUCH LSIG 4P F F

Code: 1614316

ManufacturerABB
Catalog number1SDA071350R1
EAN code8015644752002

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated voltage690 - 690V
Rated permanent current Iu630A
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionYes
Overload release current setting252.0 - 630A
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Complete device with protection unitYes
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
Device constructionBuilt-in device fixed built-in technique
Number of poles4
Position of connection for main current circuitBack side
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release945.0 - 9450A
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071350R1 | E1.2C 630 EKIP G HI-TOUCH LSIG 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated voltage

690 .. 690V

Rated permanent current Iu

630A

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Overload release current setting

252.0 .. 630A

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Complete device with protection unit

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

Device construction

Built-in device fixed built-in technique

Number of poles

4

Position of connection for main current circuit

Back side

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

945.0 .. 9450A

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.