Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Rated voltage690 - 690V
Overload release current setting252.0 - 630A
Position of connection for main current circuitBack side
Number of auxiliary contacts as change-over contact4
Number of poles4
Rated permanent current Iu630A
Motor drive integratedNo
With switched-off indicatorYes
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Adjustment range undelayed short-circuit release945.0 - 9450A
With under voltage releaseNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071356R1 | E1.2N 630 EKIP TOUCH LSIG 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Rated voltage

690 .. 690V

Overload release current setting

252.0 .. 630A

Position of connection for main current circuit

Back side

Number of auxiliary contacts as change-over contact

4

Number of poles

4

Rated permanent current Iu

630A

Motor drive integrated

With switched-off indicator

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Adjustment range undelayed short-circuit release

945.0 .. 9450A

With under voltage release

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.