Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu630A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting252.0 - 630A
Adjustment range short-term delayed short-circuit release378.0 - 6300A
Degree of protection (IP)IP30
Adjustment range undelayed short-circuit release945.0 - 9450A
With under voltage releaseNo
Type of control elementPush button
Position of connection for main current circuitBack side
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Motor drive optionalYes
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalNo
Number of poles4
Number of auxiliary contacts as change-over contact4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071356R1 | E1.2N 630 EKIP TOUCH LSIG 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

252.0 .. 630A

Adjustment range short-term delayed short-circuit release

378.0 .. 6300A

Degree of protection (IP)

IP30

Adjustment range undelayed short-circuit release

945.0 .. 9450A

With under voltage release

Type of control element

Push button

Position of connection for main current circuit

Back side

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Motor drive optional

Motor drive integrated

DIN rail (top hat rail) mounting optional

Number of poles

4

Number of auxiliary contacts as change-over contact

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.