  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu800A
Rated voltage690 - 690V
Integrated earth fault protectionYes
Number of auxiliary contacts as change-over contact4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
Number of poles4
Overload release current setting320.0 - 800A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Degree of protection (IP)IP30
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitBack side
Type of control elementPush button
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
With switched-off indicatorYes
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071377R1 | E1.2B 800 EKIP G TOUCH LSIG 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

4

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Number of poles

4

Overload release current setting

320.0 .. 800A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Degree of protection (IP)

IP30

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Back side

Type of control element

Push button

DIN rail (top hat rail) mounting optional

Motor drive integrated

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.