Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Overload release current setting320.0 - 800A
Degree of protection (IP)IP30
Rated voltage690 - 690V
Position of connection for main current circuitBack side
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Motor drive optionalYes
Motor drive integratedNo
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071386R1 | E1.2C 800 EKIP TOUCH LSIG 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Overload release current setting

320.0 .. 800A

Degree of protection (IP)

IP30

Rated voltage

690 .. 690V

Position of connection for main current circuit

Back side

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Motor drive optional

Motor drive integrated

With switched-off indicator

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

With under voltage release

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA