Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu800A
DIN rail (top hat rail) mounting optionalNo
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Overload release current setting320.0 - 800A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of control elementPush button
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Number of poles4
Motor drive integratedNo
Adjustment range undelayed short-circuit release1200.0 - 12000A
Complete device with protection unitYes
Position of connection for main current circuitBack side
Degree of protection (IP)IP30
Number of auxiliary contacts as normally open contact0
With switched-off indicatorYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071395R1 | E1.2N 800 EKIP TOUCH LSI 4P F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

800A

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Overload release current setting

320.0 .. 800A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of control element

Push button

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Number of poles

4

Motor drive integrated

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Complete device with protection unit

Position of connection for main current circuit

Back side

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.