Rated permanent current Iu800A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
Adjustment range undelayed short-circuit release1200.0 - 12000A
Overload release current setting320.0 - 800A
Motor drive integratedNo
Degree of protection (IP)IP30
With switched-off indicatorYes
Position of connection for main current circuitBack side
Type of electrical connection of main circuitBolt connection
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Type of control elementPush button
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact4
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Rated voltage690 - 690V
Integrated earth fault protectionYes
Motor drive optionalYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071396R1 | E1.2N 800 EKIP TOUCH LSIG 4P F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

800A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Overload release current setting

320.0 .. 800A

Motor drive integrated

Degree of protection (IP)

IP30

With switched-off indicator

Position of connection for main current circuit

Back side

Type of electrical connection of main circuit

Bolt connection

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Type of control element

Push button

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

4

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Rated voltage

690 .. 690V

Integrated earth fault protection

Motor drive optional

Complete device with protection unit

DIN rail (top hat rail) mounting optional