Aleta.hr
Main Product Image

1SDA071547R1 | E2.2H 800 EKIP G TOUCH LSIG 4P FHR

Code: 1614473

ManufacturerABB
Catalog number1SDA071547R1
EAN code8015644753979

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu800A
Overload release current setting320.0 - 800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Rated voltage690 - 690V
Integrated earth fault protectionYes
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact4
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release1200.0 - 12000A
Number of auxiliary contacts as normally open contact0
Type of control elementPush button
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Position of connection for main current circuitBack side
Degree of protection (IP)IP30
With switched-off indicatorYes
Complete device with protection unitYes
Motor drive optionalYes
Number of poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071547R1 | E2.2H 800 EKIP G TOUCH LSIG 4P FHR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

800A

Overload release current setting

320.0 .. 800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Rated voltage

690 .. 690V

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

4

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Number of auxiliary contacts as normally open contact

0

Type of control element

Push button

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Position of connection for main current circuit

Back side

Degree of protection (IP)

IP30

With switched-off indicator

Complete device with protection unit

Motor drive optional

Number of poles

4

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.