Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Position of connection for main current circuitBack side
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Degree of protection (IP)IP30
Number of poles4
Overload release current setting400.0 - 1000A
Rated voltage690 - 690V
Number of auxiliary contacts as normally open contact0
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
With switched-off indicatorYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release1500.0 - 15000A
Motor drive optionalYes
Type of control elementPush button
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
With under voltage releaseNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071558R1 | E2.2N 1000 EKIP HI-TOUCH LSI 4P FHR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Position of connection for main current circuit

Back side

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Degree of protection (IP)

IP30

Number of poles

4

Overload release current setting

400.0 .. 1000A

Rated voltage

690 .. 690V

Number of auxiliary contacts as normally open contact

0

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Motor drive optional

Type of control element

Push button

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

With under voltage release

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.