Aleta.hr
Main Product Image

1SDA071559R1 | E2.2N 1000 EKIP HI-TOUCH LSIG 4P FHR

Code: 1614485

ManufacturerABB
Catalog number1SDA071559R1
EAN code8015644754099

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu1000A
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact4
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Position of connection for main current circuitBack side
Number of poles4
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Adjustment range undelayed short-circuit release1500.0 - 15000A
Type of control elementPush button
Overload release current setting400.0 - 1000A
Motor drive optionalYes
Degree of protection (IP)IP30
DIN rail (top hat rail) mounting optionalNo
Motor drive integratedNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071559R1 | E2.2N 1000 EKIP HI-TOUCH LSIG 4P FHR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Position of connection for main current circuit

Back side

Number of poles

4

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Type of control element

Push button

Overload release current setting

400.0 .. 1000A

Motor drive optional

Degree of protection (IP)

IP30

DIN rail (top hat rail) mounting optional

Motor drive integrated

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.