1SDA071626R1 | E2.2N 1600 EKIP TOUCH LSIG 4P FHR

Code: 1614552

ManufacturerABB
Catalog number1SDA071626R1
EAN code8015644754761

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz66kA
Type of electrical connection of main circuitBolt connection
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Position of connection for main current circuitBack side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Overload release current setting640.0 - 1600A
Rated voltage690 - 690V
Integrated earth fault protectionYes
Device constructionBuilt-in device fixed built-in technique
Motor drive integratedNo
Number of auxiliary contacts as change-over contact4
Type of control elementPush button
With under voltage releaseNo
Motor drive optionalYes
Degree of protection (IP)IP30
Rated permanent current Iu1600A
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA071626R1 | E2.2N 1600 EKIP TOUCH LSIG 4P FHR

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Position of connection for main current circuit

Back side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Overload release current setting

640.0 .. 1600A

Rated voltage

690 .. 690V

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Motor drive integrated

Number of auxiliary contacts as change-over contact

4

Type of control element

Push button

With under voltage release

Motor drive optional

Degree of protection (IP)

IP30

Rated permanent current Iu

1600A

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.