

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
1600.0 - 4000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Number of auxiliary contacts as change-over contact
4
Rated permanent current Iu
4000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Position of connection for main current circuit
Back side
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
From same serie
1SDA071856R1 | E4.2V 4000 EKIP TOUCH LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
1600.0 .. 4000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Number of auxiliary contacts as change-over contact
4
Rated permanent current Iu
4000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Position of connection for main current circuit
Back side
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 .. 690V
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
From same serie
We use cookies to enhance your experience.