

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
2000.0 - 5000A
Rated permanent current Iu
5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
Yes
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Yes
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
With switched-off indicator
Yes
Motor drive optional
Yes
Motor drive integrated
No
From same serie
1SDA071993R1 | E6.2V/F 5000 EKIP DIP LSIG 4P FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
2000.0 .. 5000A
Rated permanent current Iu
5000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Position of connection for main current circuit
Back side
Degree of protection (IP)
IP30
With switched-off indicator
Motor drive optional
Motor drive integrated
From same serie
We use cookies to enhance your experience.