Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Overload release current setting
100.0 - 250A
Adjustment range undelayed short-circuit release
375.0 - 3750A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive optional
Yes
Type of control element
Push button
Rated permanent current Iu
250A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
1SDA072042R1 | E1.2N 250 EKIP DIP LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Overload release current setting
100.0 .. 250A
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Motor drive optional
Type of control element
Push button
Rated permanent current Iu
250A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part