Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
630A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
945.0 - 9450A
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Overload release current setting
252.0 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
With under voltage release
No
Motor drive optional
Yes
From same serie
1SDA072078R1 | E1.2N 630 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
630A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Overload release current setting
252.0 .. 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
With under voltage release
Motor drive optional
From same serie