Aleta.hr
Main Product Image

1SDA072098R1 | E1.2B 800 EKIP HI-TOUCH LSI 3P WMP

Code: 1614914

ManufacturerABB
Catalog number1SDA072098R1
EAN code8015644759483

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu800A
Rated voltage690 - 690V
Overload release current setting320.0 - 800A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Type of electrical connection of main circuitConnection at separate chassis part
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz42kA
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Number of auxiliary contacts as change-over contact4
With under voltage releaseNo
Type of control elementPush button
Number of poles3
Complete device with protection unitYes
Motor drive optionalYes
Position of connection for main current circuitConnection at separate chassis part
Motor drive integratedNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Degree of protection (IP)IP30
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA072098R1 | E1.2B 800 EKIP HI-TOUCH LSI 3P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

800A

Rated voltage

690 .. 690V

Overload release current setting

320.0 .. 800A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Type of electrical connection of main circuit

Connection at separate chassis part

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of auxiliary contacts as change-over contact

4

With under voltage release

Type of control element

Push button

Number of poles

3

Complete device with protection unit

Motor drive optional

Position of connection for main current circuit

Connection at separate chassis part

Motor drive integrated

Device construction

Built-in device slide-in technique (withdrawable)

Degree of protection (IP)

IP30

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.