Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
800A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Overload release current setting
320.0 - 800A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
With under voltage release
No
Type of control element
Push button
With switched-off indicator
Yes
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA072106R1 | E1.2C 800 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
800A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Overload release current setting
320.0 .. 800A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
With under voltage release
Type of control element
Push button
With switched-off indicator
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP30
Motor drive optional
From same serie