Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Motor drive integrated
No
Rated permanent current Iu
1000A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Motor drive optional
Yes
Overload release current setting
400.0 - 1000A
From same serie
1SDA072133R1 | E1.2B 1000 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Motor drive integrated
Rated permanent current Iu
1000A
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Motor drive optional
Overload release current setting
400.0 .. 1000A