

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
With switched-off indicator
Yes
With under voltage release
No
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
3
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
From same serie
1SDA072158R1 | E1.2N 1000 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
With switched-off indicator
With under voltage release
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
3
Motor drive integrated
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
From same serie
We use cookies to enhance your experience.