Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1500.0 - 15000A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
1SDA072159R1 | E1.2N 1000 EKIP HI-TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
We use cookies to enhance your experience.