Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Number of auxiliary contacts as change-over contact
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
400.0 - 1000A
Number of poles
3
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA072160R1 | E1.2N 1000 EKIP G HI-TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Rated voltage
690 .. 690V
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Number of auxiliary contacts as change-over contact
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
400.0 .. 1000A
Number of poles
3
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
Complete device with protection unit
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30