Aleta.hr
Main Product Image

1SDA072182R1 | E1.2C 1250 EKIP DIP LSI 3P WMP

Code: 1614978

ManufacturerABB
Catalog number1SDA072182R1
EAN code8015644760328

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device slide-in technique (withdrawable)
Rated permanent current Iu1250A
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Adjustment range undelayed short-circuit release1875.0 - 18750A
Motor drive integratedNo
Position of connection for main current circuitConnection at separate chassis part
Type of control elementPush button
Integrated earth fault protectionNo
Overload release current setting500.0 - 1250A
Degree of protection (IP)IP30
Rated voltage690 - 690V
With under voltage releaseNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Adjustment range short-term delayed short-circuit release750.0 - 12500A
Type of electrical connection of main circuitConnection at separate chassis part
Motor drive optionalYes
Number of auxiliary contacts as change-over contact4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA072182R1 | E1.2C 1250 EKIP DIP LSI 3P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device slide-in technique (withdrawable)

Rated permanent current Iu

1250A

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Motor drive integrated

Position of connection for main current circuit

Connection at separate chassis part

Type of control element

Push button

Integrated earth fault protection

Overload release current setting

500.0 .. 1250A

Degree of protection (IP)

IP30

Rated voltage

690 .. 690V

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

750.0 .. 12500A

Type of electrical connection of main circuit

Connection at separate chassis part

Motor drive optional

Number of auxiliary contacts as change-over contact

4

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.