Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu1250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release1875.0 - 18750A
Integrated earth fault protectionYes
Type of electrical connection of main circuitConnection at separate chassis part
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release750.0 - 12500A
With switched-off indicatorYes
Device constructionBuilt-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact4
Position of connection for main current circuitConnection at separate chassis part
Suitable for DIN rail (top hat rail) mountingNo
Overload release current setting500.0 - 1250A
Number of poles3
Motor drive optionalYes
Complete device with protection unitYes
Degree of protection (IP)IP30
Motor drive integratedNo
Type of control elementPush button
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA072189R1 | E1.2C 1250 EKIP HI-TOUCH LSIG 3P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

1250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

750.0 .. 12500A

With switched-off indicator

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as change-over contact

4

Position of connection for main current circuit

Connection at separate chassis part

Suitable for DIN rail (top hat rail) mounting

Overload release current setting

500.0 .. 1250A

Number of poles

3

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP30

Motor drive integrated

Type of control element

Push button

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0