Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Overload release current setting
640.0 - 1600A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
With under voltage release
No
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Motor drive integrated
No
1SDA072212R1 | E1.2B 1600 EKIP DIP LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Overload release current setting
640.0 .. 1600A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
With under voltage release
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Motor drive optional
Motor drive integrated
We use cookies to enhance your experience.