Aleta.hr
Main Product Image

1SDA072219R1 | E1.2B 1600 EKIP HI-TOUCH LSIG 3P WMP

Code: 1615005

ManufacturerRAZNO
Catalog number1SDA072219R1
Type
EAN code8015644760694

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

No

Rated voltage

690 - 690V

Rated permanent current Iu

1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Overload release current setting

640.0 - 1600A

Adjustment range undelayed short-circuit release

2400.0 - 24000A

Integrated earth fault protection

Yes

Adjustment range short-term delayed short-circuit release

960.0 - 16000A

With switched-off indicator

Yes

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

DIN rail (top hat rail) mounting optional

No

Motor drive integrated

No

Type of control element

Push button

Suitable for DIN rail (top hat rail) mounting

No

Type of electrical connection of main circuit

Connection at separate chassis part

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Yes

Degree of protection (IP)

IP30

Position of connection for main current circuit

Connection at separate chassis part

Complete device with protection unit

Yes

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA072219R1 | E1.2B 1600 EKIP HI-TOUCH LSIG 3P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated voltage

690 .. 690V

Rated permanent current Iu

1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

42kA

Overload release current setting

640.0 .. 1600A

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

With switched-off indicator

Device construction

Built-in device slide-in technique (withdrawable)

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

4

DIN rail (top hat rail) mounting optional

Motor drive integrated

Type of control element

Push button

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Connection at separate chassis part

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Degree of protection (IP)

IP30

Position of connection for main current circuit

Connection at separate chassis part

Complete device with protection unit