Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
640.0 - 1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Yes
Rated permanent current Iu
1600A
1SDA072233R1 | E1.2N 1600 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
640.0 .. 1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Rated permanent current Iu
1600A