

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Number of poles
3
Overload release current setting
320.0 - 800A
Rated permanent current Iu
800A
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
1SDA072249R1 | E2.2N 800 EKIP HI-TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Number of poles
3
Overload release current setting
320.0 .. 800A
Rated permanent current Iu
800A
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Type of control element
Push button
We use cookies to enhance your experience.