Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
No
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
3
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
With switched-off indicator
Yes
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
From same serie
1SDA072285R1 | E2.2S 1000 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
3
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
With switched-off indicator
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
From same serie