Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 - 1000A
Adjustment range undelayed short-circuit release
1500.0 - 15000A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Number of poles
3
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
1SDA072291R1 | E2.2H 1000 EKIP DIP LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
400.0 .. 1000A
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Number of poles
3
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0