

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
Integrated earth fault protection
Yes
Overload release current setting
400.0 - 1000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
With switched-off indicator
Yes
Type of control element
Push button
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA072296R1 | E2.2H 1000 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
Integrated earth fault protection
Overload release current setting
400.0 .. 1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
With switched-off indicator
Type of control element
Push button
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie
We use cookies to enhance your experience.