

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 - 1600A
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA072331R1 | E2.2B 1600 EKIP DIP LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 .. 1600A
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
From same serie
We use cookies to enhance your experience.