Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Overload release current setting
640.0 - 1600A
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Number of poles
3
Degree of protection (IP)
IP30
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive integrated
No
From same serie
1SDA072340R1 | E2.2B 1600 EKIP G HI-TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Overload release current setting
640.0 .. 1600A
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
4
Motor drive optional
With switched-off indicator
DIN rail (top hat rail) mounting optional
Number of poles
3
Degree of protection (IP)
IP30
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Motor drive integrated
From same serie