Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
640.0 - 1600A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Degree of protection (IP)
IP30
1SDA072355R1 | E2.2S 1600 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
640.0 .. 1600A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Degree of protection (IP)
IP30