Aleta.hr
Main Product Image

1SDA072360R1 | E2.2S 1600 EKIP G HI-TOUCH LSIG 3P WMP

Code: 1615146

ManufacturerABB
Catalog number1SDA072360R1
EAN code8015644762100

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Overload release current setting640.0 - 1600A
Integrated earth fault protectionYes
Type of electrical connection of main circuitConnection at separate chassis part
Rated permanent current Iu1600A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release2400.0 - 24000A
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With switched-off indicatorYes
Type of control elementPush button
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Position of connection for main current circuitConnection at separate chassis part
Number of poles3
Degree of protection (IP)IP30
Number of auxiliary contacts as change-over contact4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA072360R1 | E2.2S 1600 EKIP G HI-TOUCH LSIG 3P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Overload release current setting

640.0 .. 1600A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Rated permanent current Iu

1600A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With switched-off indicator

Type of control element

Push button

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Position of connection for main current circuit

Connection at separate chassis part

Number of poles

3

Degree of protection (IP)

IP30

Number of auxiliary contacts as change-over contact

4

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.