Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1000.0 - 2500A
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
2500A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
With under voltage release
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Number of poles
3
1SDA072416R1 | E2.2N 2500 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1000.0 .. 2500A
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
2500A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Type of control element
Push button
With under voltage release
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Number of poles
3