Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Rated voltage
690 - 690V
Integrated earth fault protection
No
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Motor drive integrated
No
Overload release current setting
1000.0 - 2500A
Degree of protection (IP)
IP30
Type of control element
Push button
1SDA072425R1 | E2.2S 2500 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2500A
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Rated voltage
690 .. 690V
Integrated earth fault protection
Number of poles
3
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Motor drive integrated
Overload release current setting
1000.0 .. 2500A
Degree of protection (IP)
IP30
Type of control element
Push button
We use cookies to enhance your experience.