Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1280.0 - 3200A
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
Type of control element
Push button
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
No
With switched-off indicator
Yes
Rated voltage
690 - 690V
Degree of protection (IP)
IP30
From same serie
1SDA072507R1 | E4.2S 3200 EKIP G TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1280.0 .. 3200A
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Type of control element
Push button
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
With switched-off indicator
Rated voltage
690 .. 690V
Degree of protection (IP)
IP30