Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Rated voltage
690 - 690V
Overload release current setting
1280.0 - 3200A
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
No
Number of poles
3
Adjustment range undelayed short-circuit release
4800.0 - 48000A
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Yes
Motor drive integrated
No
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
From same serie
1SDA072508R1 | E4.2S 3200 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Rated voltage
690 .. 690V
Overload release current setting
1280.0 .. 3200A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
Number of poles
3
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Motor drive optional
Motor drive integrated
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA