Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Complete device with protection unit
Yes
With switched-off indicator
Yes
Motor drive integrated
No
Integrated earth fault protection
Yes
Overload release current setting
1600.0 - 4000A
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Rated permanent current Iu
4000A
With under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA072586R1 | E6.2H 4000 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Complete device with protection unit
With switched-off indicator
Motor drive integrated
Integrated earth fault protection
Overload release current setting
1600.0 .. 4000A
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Type of control element
Push button
Rated permanent current Iu
4000A
With under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Degree of protection (IP)
IP30
Motor drive optional
From same serie