Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
4000A
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
No
Type of control element
Push button
Overload release current setting
1600.0 - 4000A
Number of poles
3
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA072591R1 | E6.2V 4000 EKIP DIP LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
4000A
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
Type of control element
Push button
Overload release current setting
1600.0 .. 4000A
Number of poles
3
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Motor drive optional
From same serie